Horse Construction business range tend to all over the world and service for thousands clients with products, technical,construction specialized guidance, and we witness the Chinese reinfocing brand's togther with them.
The CFRP U - shaped hoop is a U - shaped stirrup made of carbon fiber fabric. In order to fix the carbon fabric of the bottom of the beam and transfer the reliable force, when the CFRP is strengthened, the carbon fiber cloth U shaped hoop is often pasted, and the strip is not allowed only on the side of the beam.
The CFRP U – shaped hoop is a U – shaped stirrup made of carbon fiber fabric. In order to fix the carbon fabric of the bottom of the beam and transfer the reliable force, when the CFRP is strengthened, the carbon fiber cloth U shaped hoop is often pasted, and the strip is not allowed only on the side of the beam. So, when will the CFRP U shaped hoop be pasted? How to operate in the construction?
When the fiber composite material is used to reinforce the shear bearing capacity of the inclined section of the flexural member, it should be bonded into a ring hoop perpendicular to the axis of the component or other effective U – shaped hoop, and the oblique bonding method should not be used.
When the multi-layer fiber fabric attached by the bending member is allowed to cut off, the adjacent two layers of fabric should be cut off according to the principle of inner and short outer length; the truncation point of the outer fabric should be over 200mm above the inner truncation point, and the U shaped hoop should be added at the truncation point.
When reinforced concrete flexural members are subjected to normal section reinforcement, the fiber reinforced composites should be extended to the edges of the supports. The U shaped hoop (to the beam) or the horizontal bar (to the plate) should be set at the end of the fiber composite (including the truncation section) and the two sides of the concentrated load point.
The following anchorage measures should be taken when the fiber composite extends to the edge of the support and is still not satisfied with the length of the bonding extension: for the beam, no less than three U shaped hoops should be anchored uniformly within the extended length range, one of which should be set at the end of the extended length. The U type hoop is made of fiber composite material. The height of the U hoop should be the height of the beam, the flange or the cast-in-place floor should be extended to the bottom. The width of the U shaped hoop should not be less than 2/3 of the width of the reinforced fiber composite, and should not be less than 150mm; the middle hoop should not be less than the 1/2 with the width of the reinforced fiber composite strip, and should not be less than 100mm. The thickness of the U hoop shall not be less than that of the 1/2 fiber reinforced composite material.
You can find anything here you are in need of, have a trust trying on these products, you will find the big difference after that.
Weight: 600g/sqm
Thickness: 0.333mm
Density: 1.8g/cm³
Packing: 100 meters/roll
Width: 100mm, 200mm, 300mm, 500mm or to be cus
Part A (Epoxy): 20kg
Part B (Hardener): 10kg
Mix Ratio: Part A: Part B=2:1
Barrel A Size: 30*30*37cm
Bar
Volum: 75ML
Epoxy injctor is the tool to inject the epoxy into the crack.