• Good compatibility with carbon fiber;
• Strong penetration, can well infiltrate into the concrete surface;
• Aging, water resistance and chemical corrosion resistance, excellent performance;
• The adhesive layer has excellent physical mechanical properties after curing, strong toughness and a certain degree of elasticity.
Characteristics of Epoxy Resin• Good compatibility with carbon fiber; • Strong penetration, can well infiltrate into the concrete surface; • Aging, water resistance and chemical corrosion resistance, excellent performance; • The adhesive layer has excellent physical mechanical properties after curing, strong toughness and a certain degree of elasticity. |
• Used as structural resin in carbon fiber strengthening system.
• Reinforce the substrate concrete after chiseled;
• In order to improve work efficiency of the carbon fiber with concrete, can close the concrete substrate small holes.
• This product is epoxy fiber adhesive of high performance, can be used for the effective penetration bonding between many substrate materials such as concrete, steel material, ceramic, stone, wood component and many fiber fabrics such as carbon fiber, glass fiber, basalt fiber, aramid fiber.
• It is mainly used for the strengthening and reinforcement of buildings.
Application Range• Used as structural resin in carbon fiber strengthening system. • Reinforce the substrate concrete after chiseled; • In order to improve work efficiency of the carbon fiber with concrete, can close the concrete substrate small holes. • This product is epoxy fiber adhesive of high performance, can be used for the effective penetration bonding between many substrate materials such as concrete, steel material, ceramic, stone, wood component and many fiber fabrics such as carbon fiber, glass fiber, basalt fiber, aramid fiber. • It is mainly used for the strengthening and reinforcement of buildings. |
• The carbon fiber adhesive should store in a cool and dry place,storage period is 12 months. If storage period exceed 12 months, the product should be tested, if the physical and mechanical properties meet the standard requirements,you can still continue to use it.
• This product is non-toxic, belong to non-dangerous goods, transport as a goods, transport as a general chemical building materials
Transportation and Storage• The carbon fiber adhesive should store in a cool and dry place,storage period is 12 months. If storage period exceed 12 months, the product should be tested, if the physical and mechanical properties meet the standard requirements,you can still continue to use it. • This product is non-toxic, belong to non-dangerous goods, transport as a goods, transport as a general chemical building materials |
• Mix proper quantity, use up in the applicable period.
• If there is any left, the lids of A B should be covered. Do not expose it in the air.
• Construction workers should take certain protective measures.
• The construction environment should be kept ventilated during construction.
• Avoid direct sunlight and high temperature.
Attention Points• Mix proper quantity, use up in the applicable period. • If there is any left, the lids of A B should be covered. Do not expose it in the air. • Construction workers should take certain protective measures. • The construction environment should be kept ventilated during construction. • Avoid direct sunlight and high temperature. |
HM Carbon Fiber Fabric Adhesive
HM-180C3P CFRP Fabric Epoxy TDS – Horse.pdf
Technical Parameters | |||
Appearance | Component A: viscous liquid | Pot life (min) | ≥60 |
Component B: viscous liquid | Operating temperature℃ | 5~40 | |
Finger touch dry time(25℃, h) | 1~2 | ||
The basic properties after pasted carbon fiber cure | |||
Standard value of tensile strength (MPa) | ≥38 | Ultimate elongation (%) | ≥1.5 |
Elastic modulus (MPa) | ≥2400 | Mixture ratio | A:B=2:1 |
Elongation | ≥1.5% | Thixotropic index | ≥3.0 |
Non-volatile matter content | ≥99% | Distortion temperature | ≥65℃ |
Steel-steel adhesive tensile strength | ≥40Mpa | Steel – steel T impact stripping length | ≤20mm |
Long-term performance | Wet and heat ageing
resistance ability |
Compared with the short-term results at room temperature,
the decrease rate of shear strength: ≤12% |
|
Heat aging
resistance |
Compared with the short-term results at same temperature 10min,
the decrease rate of shear strength: ≤5% |
||
Freezing and thawing
resistance ability |
Compared with room temperature, short-term results,
the shear strength decrease rate is not greater than 5% |
||
Fatigue stress
resistance ability |
After2×106 times continuous sine wave fatigue loads,
specimen does not destroy |
||
Resistance to stress
for a long time |
Steel – steel tensile shear specimens does not destroy,
and creep deformation value is less than 0.4 mm |
||
Resistance to corrosion medium | Resistance to salt
fog effect |
Compared with the control group, the strength decrease rate: ≤5%,
and shall not have cracks or come unglued |
|
Alkaline medium
resistance ability |
Compared with the control group, the strength does not decrease,
and as the concrete damage, and shall not have cracks or come unglued |
||
Acid medium
resistance ability |
Concrete damage, and shall not have cracks or degumming |
The properties after carbon fiber cure | |||||
Colloidal performance | Compressive strength(MPa) | ≥70.0 | Working
performance |
Nonvertical mobility(mm), 30℃ | 2.0 |
Tensile strength(MPa) | ≥40.0 | Operable time(min), 30℃ | >40 | ||
Bending Strength(MPa) | ≥50.0 | Applicable Temperature(℃) | 5~40 | ||
Elastic strength(MPa) | ≥2500 | ||||
Bonding capacity | Steel-steel tensile shear strength(MPa) | ≥14 | Mixing ratio | A:B=2:1 | |
Pulling bonding strength along
with concrete(MPa) |
≥2.5 | Curing time(d),25℃ | 3~7 | ||
Steel-concrete tensile | C60 concrete damage |
Carbon fiber reinforced polymer(CFRP fabric/wrap/sheet) for structural strengthening of column,beam,slab,wall
>>The treatment of concrete surface
The cosmetic layer, oil, dirt etc. Of concrete surface should be chiseled off and then rubbed off 1 ~2 mm thick surface layer with the
angle grinder, concrete components should be handled by chamfering on the corner, dust was blew out with compressed air after the
completion Of polishing, and finally the surface was wiped by cotton cloth dipped in acetone, and kept dry for use. If the concrete
needed to strengthen existed cracks, first choose HM-120M perfusion adhesive or HM-120L pouring crack adhesive to perfuse according
to the size of crack, and then strengthen.
>>Primer construction
When construction, two components of primer A and B were weighed according to the stipulated proportion of preparing glue, and
dumped into a clean container and stirred to uniformity (when mixing, best mix along the same direction to avoid the air from forming
air bubbles.) Brush or roller brush was used to evenly brush on the concrete surface, after the glue surface layer dried, it should be
brushed several times depending on the particular circumstances, but the coating thickness did not exceed 0.4 mm, and it should
not be missed out to brush, or have flowing or bubbles, waiting for glue curing (curing time was depended on the site temperature,
it was appropriate when finger felt dry, generally not less than 2 hours), then the next process was proceeded. The glue prepared
every time should be used up one time during the applicable period of the glue.
>>Leveling construction
The pores and defects on concrete surface were filled by leveling adhesive.When depression area was existed, the prepared leveling
adhesive was used to repair and fill through scraper embedding and scraping, the position emerging altitude difference such as the
joint of templates should be filled by leveling adhesive, which tried to minimize the height difference. The treatment of corner was that
it was repaired to smooth arc through leveling adhesive, its radius was not more than 20mm. After the leveling adhesive cured (curing
time was depended on the site temperature, it was appropriate when finger felt dry, generally not less than 2 hours), the next process
should be proceeded further.
>>Paste of carbon fiber cloth
Carbon fiber impregnated adhesive was smeared to the pasted area evenly,the corner site was more smeared appropriately. Paste after
hauling carbon fiber cloth tight and alignment, use a plastic scraper or roller (a paint roller that the villus was removed outside) to roll
repeatedly along the same direction, until the glue compound exuded. And then smear impregnated adhesive to the outside surface
of the carbon fiber cloth evenly, and roll repeatedly, 50 that the impregnated adhesive can immerse the carbon fiber cloth in two ways,
if it is multi-paste, until your fingers touch dry, the next layer of paste can be beginner. If the carbon fiber cloth needs overlapping
>>Curing and conservation
Prevent rain or moisture 24 hours after the completion of construction, and pay attention to protection against a hard Object bumping
into the surface of the construction. When the average air temperature is 20 , 25 ℃ , the curing time is not less than 3 days; when
the average air temperature is 10 ℃, the curing time is not less than 7 days.